2.6l silica gel point glue machine is used to push out the glue solution through the glue gun in the set time with air pressure. The time of each injection is controlled by timer to ensure the same amount of each injection. As long as the air pressure, time and selection of the appropriate needle, can easily change each infusion volume
1. 2.6l silica gel point glue machine is used to push out the glue solution through the glue gun within the set time with air pressure. The time of each injection is controlled by timer to ensure the same amount of each injection; It is easy to change the amount of each injection as long as the air pressure, time and proper needle are adjusted.
2. All kinds of glue can be injected into 2.6l barrel, and various sizes of steel pipe needles can be provided according to the needs of users;
3. The cabinet type dispensing machine has a strong, simple appearance and high security, which can prevent the damage caused by the damage caused by the damage, shedding and aging of pneumatic components;
4. The pressurized point glue machine can pressurize the glue liquid by the booster pump to improve the output speed and productivity.
1. Automatic timing: 0-99.99s;
2. Manual timing: hand press and foot switch;
3. Input power supply voltage: 220-240v 50Hz parts voltage is DC24V;
4. Working pressure: 4-7.5bar;
1. Connect the air source and power supply to the lower right of the door plate of the electric box. At the same time, the pressure switch on the panel of the electric box is unplugged to the "off" state, and the air pressure in the bucket is emptied;Pay attention! The pressure gauge on the pressure barrel cover indicates that the needle points to "0" to confirm that the pressure in the pressure barrel has been exhausted;3. Open two box cover locks, grasp the left and right box cover handle, lift the box cover up and put it on one side;
4. Unscrew the barrel cover nut counterclockwise to make it exit the insert groove of the pressure cylinder cover and open the cover; The pressure cylinder cover cannot be opened, usually because the pressure cylinder on the cylinder cover has not been recovered. Connect the air source to ensure that the pressure switch of the plastic barrel is in the closed state;
5. Unscrew the cap of the bottle and check whether there is any solidified glue or foreign body in the discharge opening of the bottle. If so, please clean it out. If the plastic barrel is not inserted to the end, causing pressure on the cylinder cover, please pay attention to whether there is dry glue or foreign matter on the bottom of the barrel. Make sure that the pressure of the discharge port and the discharge port of the bottom of the barrel are in place;
6. Put the pressure cylinder cover on, insert the cylinder cover nut and screw rod into the cylinder cover's insert slot, and screw clockwise;
7. Unplug the pressure switch of the plastic bucket on the panel of the electric box to "open", and add air pressure to the bucket. Adjust the pressure through the pressure regulating valve of the plastic barrel on the panel of the electric box. If the pressure is high, the glue discharging speed will be fast. If the pressure is low, the glue discharging speed will be slow. (the standard pressure of the pressure barrel is above 4-5kg)
8. Adjust the pressure regulating valve of the hydraulic pump on the electric box to make the booster pump work. The higher the pressure, the faster the pump. The faster the glue comes out. Note that the pressure must not be too high; (the standard pressure of working pressure of hydraulic pump is above 2-5kg)
9. You can choose the size of the dispensing needle when dispensing. If the dispensing needle is too small, it will come out slowly. 10. When the pressure cylinder is not used or moved to another work station and removed, the pressure in the pressure cylinder shall be discharged first, and then the pressure regulating valve on the electric box shall be set at "0", so that the pressurization shall be stopped first, and then the pedal switch shall be applied, and the glue gun shall be released for about 30 seconds, and the pedal switch shall be released;
(note! Keep the glue bottle inside the pressure cylinder. Avoid contact with air at the quick plug and glue mouth inside the cylinder. Otherwise, the glue mouth will solidify, making it impossible to use.
1. The dispensing gun shall be cleaned every 10-15 days, and the muzzle and gasket of the gun shall be changed
2. If there is any gum on the shaft of the booster pump, it shall be cleaned regularly. Replace the central shaft rubber ring;
1. Check whether air pressure and power supply are normal;
2. Whether the checkpoint microneedle has been blocked or replaced;
3. Whether the dispensing gun is working;
4. Is the solenoid valve responsive
5. Whether the foot switch or the hand switch is damaged;
6. Whether the relay is damaged;
7. whether the parking time is too long, and the nozzle and the pressure bucket at the bottom are blocked. Clean the glue gun and the glue mouth.
1. Leakage of glue at the end of the nozzle of the dispensing gun:
A. The rubber ring of the nozzle is damaged and replaced;
B. Loose the central axle nut of the nozzle and tighten the nut;
C. Loose cap at the head of the gun and loose rubber ring. Tighten the aluminum cap in front of the nozzle.
D. The axis of the dispensing gun is not correct. When installing the gun, press down the central axle nut, tighten the front aluminum cap to press the rubber ring, tighten the screw at the bottom of the barrel, and finally tighten the two screws on the fixing cylinder.
E. Whether the time of the relay is set." 00S01" delay of 0.01 second is normal. We don't normally say "M" and "H". S is seconds, M is minutes, H is hours;
2. Leakage of glue at the bottom of the dispenser :(joint of the barrel and cylinder)
A. the glue on the central shaft dries out and the sealing ring wears away. Remove the gun, scrape the dry glue of the shaft, and replace the sealing ring;
1. Leakage of glue on the central shaft. If the sealing ring of the central shaft is damaged, the sealing ring can be replaced.
2, the booster pump does not work :
A, check whether there is pressure to; & have spent & have spent & have spent & have spent & have spent B. there is something wrong with the induction switch;
C, whether the double-ended electromagnetic valve in the electric box is normal, and whether the coil is broken;
D, the booster pump is still working up and down without glue. Two sealing rings in the pump may be damaged, so the pump can work up and down without sealing.